Ham Tech Prep

Amateur Extra › E0

E0 Safety

12 questions in the pool. Your exam will include 1, one from each group below.

Practice E0 now

E0A

Safety: RF radiation hazards; hazardous materials; grounding

E0A01

What is the primary function of an external earth connection or ground rod?

  1. A. Prevent static build up on power lines
  2. B. Lightning charge dissipation
  3. C. Reduce RF current flow between pieces of equipment
  4. D. Protect breaker panel from power surges
Show the answer and explanation

Answer: B. Lightning charge dissipation

An external ground rod's main job is to dissipate lightning charge safely into the earth. It does little to reduce RF currents between equipment.

Tip: Ground rod = lightning path to earth.

E0A02

When evaluating RF exposure levels from your station at a neighbor's home, what must you do?

  1. A. Ensure signals from your station are less than the controlled maximum permissible exposure (MPE) limits
  2. B. Ensure signals from your station are less than the uncontrolled maximum permissible exposure (MPE) limits
  3. C. Ensure signals from your station are less than the controlled maximum permissible emission (MPE) limits
  4. D. Ensure signals from your station are less than the uncontrolled maximum permissible emission (MPE) limits
Show the answer and explanation

Answer: B. Ensure signals from your station are less than the uncontrolled maximum permissible exposure (MPE) limits

A neighbor's home is an area where people are not aware of or in control of their exposure. So your station must meet the stricter uncontrolled maximum permissible exposure (MPE) limits there. MPE stands for exposure, not emission.

Tip: Neighbors get uncontrolled (stricter) limits.

E0A03

Over what range of frequencies are the FCC human body RF exposure limits most restrictive?

  1. A. 300 kHz - 3 MHz
  2. B. 3 - 30 MHz
  3. C. 30 - 300 MHz
  4. D. 300 - 3000 MHz
Show the answer and explanation

Answer: C. 30 - 300 MHz

The FCC exposure limits are lowest from 30 to 300 MHz because the human body absorbs RF most efficiently in that range, near its resonant frequencies.

Tip: Body resonance: 30 to 300 MHz.

E0A04

When evaluating a site with multiple transmitters operating at the same time, the operators and licensees of which transmitters are responsible for mitigating over-exposure situations?

  1. A. Each transmitter that produces 20 percent or more of its MPE limit in areas where the total MPE limit is exceeded
  2. B. Each transmitter operating with a duty cycle greater than 25 percent
  3. C. Each transmitter that produces 5 percent or more of its MPE limit in areas where the total MPE limit is exceeded
  4. D. Each transmitter operating with a duty cycle greater than 50 percent
Show the answer and explanation

Answer: C. Each transmitter that produces 5 percent or more of its MPE limit in areas where the total MPE limit is exceeded

At a multi-transmitter site where the total MPE limit is exceeded, every transmitter producing 5 percent or more of its MPE limit there shares responsibility for fixing it.

Tip: 5 percent or more means you share.

E0A05

What hazard is created by operating at microwave frequencies?

  1. A. Microwaves are ionizing radiation
  2. B. The high gain antennas commonly used can result in high exposure levels
  3. C. Microwaves are in the frequency range where wave velocity is higher
  4. D. The extremely high frequency energy can damage the joints of antenna structures
Show the answer and explanation

Answer: B. The high gain antennas commonly used can result in high exposure levels

Microwaves are non-ionizing, but the high-gain antennas common at those frequencies focus energy into narrow beams that can create high exposure levels.

Tip: High gain dishes concentrate the energy.

E0A06

Why are there separate electric (E) and magnetic (H) MPE limits at frequencies below 300 MHz?

  1. A. The body reacts to electromagnetic radiation from both the E and H fields
  2. B. Ground reflections and scattering cause the field strength to vary with location
  3. C. E field and H field radiation intensity peaks can occur at different locations
  4. D. All these choices are correct
Show the answer and explanation

Answer: D. All these choices are correct

Below 300 MHz, the body reacts to both E and H fields, reflections make field strength vary by location, and E and H peaks can occur at different places. So both must be evaluated separately.

Tip: E and H differ near the antenna.

E0A07

What is meant by “100% tie-off” regarding tower safety?

  1. A. All loose ropes and guys secured to a fixed structure
  2. B. At least one lanyard attached to the tower at all times
  3. C. All tools secured to the climber's harness
  4. D. All circuit breakers feeding power to the tower must be tied closed with tape, cable, or ties
Show the answer and explanation

Answer: B. At least one lanyard attached to the tower at all times

100% tie-off means the climber always has at least one lanyard attached to the tower, even while moving a second lanyard.

Tip: Always clipped in.

E0A08

What does SAR measure?

  1. A. Signal attenuation ratio
  2. B. Signal amplification rating
  3. C. The rate at which RF energy is absorbed by the body
  4. D. The rate of RF energy reflected from stationary terrain
Show the answer and explanation

Answer: C. The rate at which RF energy is absorbed by the body

SAR (specific absorption rate) measures the rate at which RF energy is absorbed by the body, usually in watts per kilogram.

Tip: SAR = absorption by the body.

E0A09

Which of the following types of equipment are exempt from RF exposure evaluations?

  1. A. Transceivers with less than 7 watts of RF output
  2. B. Antennas that radiate only in the near field
  3. C. Hand-held transceivers sold before May 3, 2021
  4. D. Dish antennas less than one meter in diameter
Show the answer and explanation

Answer: C. Hand-held transceivers sold before May 3, 2021

Under the FCC's RF exposure rules, hand-held transceivers sold before May 3, 2021 are exempt from RF exposure evaluations. Low power alone does not exempt other equipment.

Tip: Old handhelds: before May 3, 2021.

E0A10

When must an RF exposure evaluation be performed on an amateur station operating on 80 meters?

  1. A. An evaluation must always be performed
  2. B. When the ERP of the station is less than 10 watts
  3. C. When the station's operating mode is CW
  4. D. When the output power from the transmitter is less than 100 watts
Show the answer and explanation

Answer: A. An evaluation must always be performed

On 80 meters an RF exposure evaluation must always be performed. Even deciding that a station qualifies for an exemption requires evaluating its power and distance.

Tip: 80 m: always evaluate.

E0A11

To what should lanyards be attached while climbing?

  1. A. Antenna mast
  2. B. Guy brackets
  3. C. Tower rungs
  4. D. Tower legs
Show the answer and explanation

Answer: D. Tower legs

Lanyards should be attached to the tower legs, the strongest structural members. Rungs, guy brackets, and masts may not hold a fall.

Tip: Clip to the legs.

E0A12

Where should a shock-absorbing lanyard be attached to a tower when working above ground?

  1. A. Above the climber's head level
  2. B. To the belt of the fall-arrest harness
  3. C. Even with the climber's waist
  4. D. To the next lowest set of guys
Show the answer and explanation

Answer: A. Above the climber's head level

A shock-absorbing lanyard should be attached above the climber's head. This limits the fall distance before the lanyard catches.

Tip: Clip high, fall short.

Practice E0 with scoring Take a 50-question practice exam