Ham Tech Prep

Technician › T0

T0 Safety

36 questions in the pool. Your exam will include 3, one from each group below.

Practice T0 now

T0A

Power circuits and hazards: hazardous voltages, fuses and circuit breakers, grounding, electrical code compliance; Lightning protection; Battery safety

T0A01

Which of the following is a safety hazard of a 12-volt storage battery that lacks internal protection circuitry?

  1. A. Touching both terminals with your hands can cause electrical shock
  2. B. Shorting the terminals can cause burns, fire, or an explosion
  3. C. RF emissions from a nearby transmitter can cause the electrolyte to emit poison gas
  4. D. All these choices are correct
Show the answer and explanation

Answer: B. Shorting the terminals can cause burns, fire, or an explosion

Shorting the terminals can cause burns, fire, or an explosion. A 12-volt storage battery can deliver a huge current through a short, such as a dropped wrench or a ring, which can get red hot and melt. 12 volts usually won't shock you through dry skin, but the short-circuit danger is very real.

Tip: Low voltage, huge current: never short a battery.

T0A02

What health hazard is posed by electrical current flowing through the body?

  1. A. It may cause injury by heating body tissue
  2. B. It may disrupt the electrical functions of cells
  3. C. It may cause involuntary muscle contractions
  4. D. All these choices are correct
Show the answer and explanation

Answer: D. All these choices are correct

All these choices are correct. Current through the body can heat and burn tissue, disrupt the electrical signals of cells (including the heart), and cause muscles to contract so you may be unable to let go. Even fairly small currents can be deadly.

Tip: Current through you: burns, heart, grip.

T0A03

In the United States, what circuit does black wire insulation indicate in a three-wire 120 V AC cable?

  1. A. Neutral
  2. B. Hot
  3. C. Equipment ground
  4. D. Negative
Show the answer and explanation

Answer: B. Hot

In US three-wire 120 V AC cable, black insulation marks the hot wire. White is neutral and green or bare copper is the equipment ground. Always treat black as live and dangerous.

Tip: Black is hot, white is neutral, green is ground.

T0A04

What is the purpose of a fuse in an electrical circuit?

  1. A. To prevent power supply ripple from damaging a component
  2. B. To remove power in case of an overload
  3. C. To limit current and prevent shocks
  4. D. All these choices are correct
Show the answer and explanation

Answer: B. To remove power in case of an overload

A fuse removes power in case of an overload. If too much current flows, the fuse melts and opens the circuit, protecting wiring and equipment from overheating. A fuse does not prevent electric shock.

Tip: Fuse blows to stop too much current.

T0A05

Why should a 5-ampere fuse never be replaced with a 20-ampere fuse?

  1. A. The larger fuse would be likely to blow because it is rated for higher current
  2. B. The power supply ripple would greatly increase
  3. C. Excessive current could cause a fire
  4. D. Voltage drop in the higher current fuse could result in excessively low voltage to the device
Show the answer and explanation

Answer: C. Excessive current could cause a fire

A 20-amp fuse in place of a 5-amp fuse lets excessive current flow, which could cause a fire. The wiring and parts were designed for 5 amps, and they can overheat long before a 20-amp fuse blows. Always replace a fuse with the same rating.

Tip: Same fuse rating only, or risk fire.

T0A06

What is a good way to guard against electrical shock at your station?

  1. A. Use three-wire cords and plugs for all AC powered equipment
  2. B. Connect all AC powered station equipment to a common safety ground
  3. C. Ensure all capacitors used for high-voltage DC are fully discharged before working inside equipment
  4. D. All these choices are correct
Show the answer and explanation

Answer: D. All these choices are correct

All these choices are correct. Use three-wire cords and plugs, connect AC-powered equipment to a common safety ground, and make sure high-voltage capacitors are fully discharged before working inside equipment. Each step lowers the chance of a dangerous shock.

Tip: Ground it, plug it right, discharge it.

T0A07

Where should a lightning arrester be installed in a coaxial feed line?

  1. A. At the output connector of a transceiver
  2. B. At the antenna feed point
  3. C. At the AC power service panel
  4. D. On a grounded panel near where feed lines enter the building
Show the answer and explanation

Answer: D. On a grounded panel near where feed lines enter the building

A lightning arrester belongs on a grounded panel near where feed lines enter the building. This sends lightning energy to ground before it gets inside the house. Putting it at the radio would let the surge come indoors first.

Tip: Stop lightning at the door, not at the radio.

T0A08

Where should a fuse or circuit breaker be installed in a 120V AC power circuit?

  1. A. In series with the hot conductor only
  2. B. In series with the hot and neutral conductors
  3. C. In parallel with the hot conductor only
  4. D. In parallel with the hot and neutral conductors
Show the answer and explanation

Answer: A. In series with the hot conductor only

A fuse or circuit breaker goes in series with the hot conductor only. In series, all the current passes through it, so it can cut the power. Putting it in the neutral could leave equipment still connected to the hot wire after the fuse opens.

Tip: Fuse in series, on the hot wire.

T0A09

What should be done to all external ground rods or earth connections?

  1. A. Waterproof them with silicone caulk or electrical tape
  2. B. Keep them as far apart as possible
  3. C. Bond them together with heavy wire or conductive strap
  4. D. Tune them for resonance on the lowest frequency of operation
Show the answer and explanation

Answer: C. Bond them together with heavy wire or conductive strap

All external ground rods or earth connections should be bonded together with heavy wire or conductive strap. This keeps them at the same voltage so dangerous currents don't flow between them during a lightning strike or electrical fault. Ground rods do not get tuned like antennas.

Tip: Bond all grounds together.

T0A10

What hazard exists when rapidly charging or discharging an unprotected battery?

  1. A. Overheating or out-gassing
  2. B. Excess output ripple
  3. C. Electric shock
  4. D. Overvoltage
Show the answer and explanation

Answer: A. Overheating or out-gassing

Rapidly charging or discharging an unprotected battery can cause overheating or out-gassing. The battery may release flammable or harmful gases, and some types can catch fire or burst. Charge and discharge within the battery's ratings.

Tip: Fast charge or drain = heat and gas.

T0A11

What hazard exists in a power supply immediately after turning it off?

  1. A. Circulating currents in the dc filter
  2. B. Leakage flux in the power transformer
  3. C. Voltage transients from kickback diodes
  4. D. Charge stored in filter capacitors
Show the answer and explanation

Answer: D. Charge stored in filter capacitors

Right after a power supply is turned off, charge stored in the filter capacitors can still give a dangerous shock. Big capacitors can hold a charge for a long time. Make sure they are fully discharged before touching anything inside.

Tip: Off isn't safe: capacitors stay charged.

T0A12

Which of the following precautions should be taken when measuring high voltages with a voltmeter?

  1. A. Ensure that the voltmeter has very low impedance
  2. B. Ensure that the voltmeter and its leads are rated for use at the voltages being measured
  3. C. Ensure that the circuit is grounded through the voltmeter
  4. D. Ensure that the voltmeter is set to the correct frequency
Show the answer and explanation

Answer: B. Ensure that the voltmeter and its leads are rated for use at the voltages being measured

When measuring high voltages, make sure the voltmeter and its leads are rated for the voltages being measured. Under-rated meters or leads can break down and expose you to deadly voltage. A good voltmeter has high impedance, not low, so that choice is wrong.

Tip: Check the meter and lead voltage ratings first.

T0B

Antenna safety: tower safety and grounding, installing antennas, antenna supports

T0B01

Which of the following is good practice when installing ground wires on a tower for lightning protection?

  1. A. Put a drip loop in the ground connection to prevent water damage to the ground system
  2. B. Make sure all ground wire bends are right angles
  3. C. Ensure that connections are short and direct
  4. D. All these choices are correct
Show the answer and explanation

Answer: C. Ensure that connections are short and direct

Lightning ground connections should be short and direct. Lightning current takes the easiest path, and long runs or sharp bends make it more likely to jump to something else. Drip loops and right-angle bends are wrong for ground wires.

Tip: Lightning ground: short and straight.

T0B02

What is required when climbing an antenna tower?

  1. A. Have sufficient training on safe tower climbing techniques
  2. B. Use appropriate tie-off to the tower at all times
  3. C. Always wear an approved climbing harness
  4. D. All these choices are correct
Show the answer and explanation

Answer: D. All these choices are correct

All these choices are correct. You need proper training in safe climbing, an approved climbing harness, and you must stay tied off to the tower at all times. A fall from a tower can kill.

Tip: Training, harness, always tied off.

T0B03

Under what circumstances is it safe to climb a tower without a helper or observer?

  1. A. When no electrical work is being performed
  2. B. When no mechanical work is being performed
  3. C. When the work being done is not more than 20 feet above the ground
  4. D. Never
Show the answer and explanation

Answer: D. Never

It is never safe to climb a tower without a helper or observer. Someone on the ground can call for help, hand up tools, and watch for danger. Even a short or simple job can go wrong.

Tip: Never climb alone.

T0B04

Which of the following is an important safety precaution to observe when putting up an antenna tower?

  1. A. Wear a ground strap connected to your wrist at all times
  2. B. Insulate the base of the tower to avoid lightning strikes
  3. C. Look for and stay clear of any overhead electrical wires
  4. D. All these choices are correct
Show the answer and explanation

Answer: C. Look for and stay clear of any overhead electrical wires

When putting up a tower, look for and stay clear of any overhead electrical wires. Contact with power lines can kill you instantly. Insulating the tower base does not prevent lightning strikes, and a wrist strap isn't needed.

Tip: Look up for power lines before you raise anything.

T0B05

What is the purpose of a safety wire through a turnbuckle used to tension guy lines?

  1. A. Secure the guy line if the turnbuckle breaks
  2. B. Prevent loosening of the turnbuckle from vibration
  3. C. Provide a ground path for lightning strikes
  4. D. Provide an ability to measure for proper tensioning
Show the answer and explanation

Answer: B. Prevent loosening of the turnbuckle from vibration

A safety wire through a turnbuckle prevents it from loosening due to vibration. Wind shakes guy lines all the time, and a loose turnbuckle could let a guy line go slack. The wire locks it in place.

Tip: Safety wire keeps the turnbuckle from turning.

T0B06

What is the minimum safe distance from a power line to allow when installing an antenna?

  1. A. Add the height of the antenna to the height of the power line and multiply by a factor of 1.5
  2. B. The height of the power line above ground
  3. C. 1/2 wavelength at the operating frequency
  4. D. Enough so that if the antenna falls, no part of it can come within 10 feet of the power wires
Show the answer and explanation

Answer: D. Enough so that if the antenna falls, no part of it can come within 10 feet of the power wires

Keep the antenna far enough away that if it falls, no part of it can come within 10 feet of the power wires. Plan for the worst case, a falling antenna or tower. Power line contact can be deadly.

Tip: If it falls, stay 10 feet clear of power lines.

T0B07

Which of the following is an important safety rule to remember when using a crank-up tower?

  1. A. This type of tower must never be painted
  2. B. This type of tower must never be grounded
  3. C. This type of tower must not be climbed unless it is retracted, or mechanical safety locking devices have been installed
  4. D. All these choices are correct
Show the answer and explanation

Answer: C. This type of tower must not be climbed unless it is retracted, or mechanical safety locking devices have been installed

A crank-up tower must not be climbed unless it is retracted or mechanical safety locking devices have been installed. Otherwise a section could slide down and crush or injure the climber. Crank-up towers can be painted and should be grounded.

Tip: Crank it down before you climb.

T0B08

Which is a proper grounding method for a tower?

  1. A. A single four-foot ground rod, driven into the ground no more than 12 inches from the base
  2. B. A ferrite-core RF choke connected between the tower and ground
  3. C. A connection between the tower base and a cold-water pipe
  4. D. Separate eight-foot ground rods for each tower leg, bonded to the tower and each other
Show the answer and explanation

Answer: D. Separate eight-foot ground rods for each tower leg, bonded to the tower and each other

A proper tower ground uses separate eight-foot ground rods for each tower leg, bonded to the tower and each other. This gives lightning many good paths into the earth. One short rod is not enough, and a cold-water pipe is not a proper lightning ground.

Tip: Eight-foot rod per leg, all bonded.

T0B09

Why should you avoid attaching an antenna to a utility pole?

  1. A. The antenna will not work properly because of induced voltages
  2. B. The antenna may unbalance the power transformer, causing power fluctuations
  3. C. The antenna could contact high-voltage power lines
  4. D. All these choices are correct
Show the answer and explanation

Answer: C. The antenna could contact high-voltage power lines

You should avoid attaching an antenna to a utility pole because the antenna could contact high-voltage power lines. That could electrocute you or others. Utility poles belong to the power or phone company, not to hams.

Tip: Utility poles are for utilities, not antennas.

T0B10

Which of the following is true when installing grounding conductors used for lightning protection?

  1. A. Use only non-insulated wire
  2. B. Wires must be carefully routed with precise right-angle bends
  3. C. Sharp bends must be avoided
  4. D. Common grounds must be avoided
Show the answer and explanation

Answer: C. Sharp bends must be avoided

Sharp bends must be avoided in lightning grounding conductors. Lightning current tends not to follow sharp bends and can jump off to nearby objects. Use gentle curves and short, direct runs.

Tip: Lightning hates sharp turns.

T0B11

Which of the following establishes grounding requirements for an amateur radio tower or antenna?

  1. A. FCC Part 97 rules
  2. B. Local electrical codes
  3. C. FAA tower lighting regulations
  4. D. UL recommended practices
Show the answer and explanation

Answer: B. Local electrical codes

Local electrical codes set grounding requirements for amateur towers and antennas. FCC Part 97 covers radio operation, not electrical grounding. FAA rules cover lighting tall towers near airports.

Tip: Grounding rules come from local electrical code.

T0C

RF hazards: radiation exposure, proximity to antennas, recognized safe power levels, radiation types, duty cycle

T0C01

What type of radiation are radio signals?

  1. A. Gamma radiation
  2. B. Ionizing radiation
  3. C. Alpha radiation
  4. D. Non-ionizing radiation
Show the answer and explanation

Answer: D. Non-ionizing radiation

Radio signals are non-ionizing radiation. They do not have enough energy to knock electrons from atoms the way X-rays or gamma rays do. However, strong RF can still heat body tissue, so exposure limits still apply.

Tip: Radio waves: non-ionizing, but still can heat.

T0C02

Which of the following bands has the lowest maximum permissible exposure for RF safety?

  1. A. 3.5 MHz
  2. B. 50 MHz
  3. C. 440 MHz
  4. D. 1296 MHz
Show the answer and explanation

Answer: B. 50 MHz

50 MHz has the lowest maximum permissible exposure (MPE) of these choices. The FCC limits are strictest from 30 to 300 MHz, where the human body absorbs RF energy most easily. 3.5, 440, and 1296 MHz all have higher allowed levels.

Tip: Strictest limits: 30-300 MHz, like 6 meters.

T0C03

How does the allowable power density for RF safety change if duty cycle changes from 100 percent to 50 percent?

  1. A. It increases by a factor of 3
  2. B. It decreases by 50 percent
  3. C. It increases by a factor of 2
  4. D. There is no adjustment allowed for lower duty cycle
Show the answer and explanation

Answer: C. It increases by a factor of 2

When duty cycle drops from 100 percent to 50 percent, the allowable power density increases by a factor of 2. Exposure limits are based on average exposure, and transmitting half the time halves the average. So the peak level can be twice as high for the same average.

Tip: Half the time on, twice the allowed level.

T0C04

What factors affect the RF exposure of people near an amateur station antenna?

  1. A. Frequency and power level of the RF field
  2. B. Distance from the antenna to a person
  3. C. Radiation pattern of the antenna
  4. D. All these choices are correct
Show the answer and explanation

Answer: D. All these choices are correct

All these choices are correct. RF exposure depends on the frequency and power of the signal, the distance from the antenna to a person, and the antenna's radiation pattern. All must be considered in a station evaluation.

Tip: Power, frequency, distance, pattern: all count.

T0C05

Why do exposure limits vary with frequency?

  1. A. Lower frequency RF fields have more energy than higher frequency fields
  2. B. Lower frequency RF fields do not penetrate the human body
  3. C. Higher frequency RF fields are transient in nature
  4. D. The human body absorbs more RF energy at some frequencies than at others
Show the answer and explanation

Answer: D. The human body absorbs more RF energy at some frequencies than at others

Exposure limits vary with frequency because the human body absorbs more RF energy at some frequencies than at others. The body absorbs the most in roughly the 30-300 MHz range. Lower frequencies do not have more energy, so that choice is wrong.

Tip: Body absorbs some frequencies more.

T0C06

Which of the following is an acceptable method to determine whether your station complies with FCC RF exposure regulations?

  1. A. By calculation based on FCC OET Bulletin 65
  2. B. By calculation based on computer modeling
  3. C. By measurement of field strength using calibrated equipment
  4. D. All these choices are correct
Show the answer and explanation

Answer: D. All these choices are correct

All these choices are correct. You may check RF exposure compliance by calculation using FCC OET Bulletin 65, by computer modeling, or by measuring field strength with calibrated equipment.

Tip: Calculate, model, or measure: all OK.

T0C07

What hazard is created by touching an antenna during a transmission?

  1. A. Electrocution
  2. B. RF burn to skin
  3. C. Exposure to ionizing radiation
  4. D. All these choices are correct
Show the answer and explanation

Answer: B. RF burn to skin

Touching an antenna during a transmission can cause an RF burn to the skin. RF energy flowing into your body at the contact point can burn painfully and deeply. RF is non-ionizing, so that choice is wrong. Never touch an antenna while transmitting.

Tip: Hands off antennas while transmitting.

T0C08

Which of the following actions can reduce exposure to RF radiation?

  1. A. Relocate antennas
  2. B. Relocate the transmitter
  3. C. Increase the duty cycle
  4. D. All these choices are correct
Show the answer and explanation

Answer: A. Relocate antennas

Relocating antennas can reduce exposure to RF radiation. Moving them farther from people lowers the field strength where people are. Moving the transmitter alone doesn't change where the antenna radiates, and increasing duty cycle raises exposure.

Tip: Move the antenna away from people.

T0C09

How can you make sure your station stays in compliance with RF safety regulations?

  1. A. By informing the FCC of any changes made in your station
  2. B. By re-evaluating the station whenever an item in the transmitter or antenna system is changed
  3. C. By making sure your antennas have low SWR
  4. D. By using only Underwriter Laboratories approved transmitting equipment
Show the answer and explanation

Answer: B. By re-evaluating the station whenever an item in the transmitter or antenna system is changed

Stay in compliance by re-evaluating your station whenever an item in the transmitter or antenna system is changed. A new antenna, more power, or a different band can change RF exposure. Low SWR does not mean safe exposure, and the FCC does not need to be notified.

Tip: Change the station? Re-check RF exposure.

T0C10

Why is duty cycle one of the factors used to determine safe RF radiation exposure levels?

  1. A. It affects the average exposure to radiation
  2. B. It affects the peak exposure to radiation
  3. C. It takes into account the antenna feed line loss
  4. D. It takes into account the thermal effects of the final amplifier
Show the answer and explanation

Answer: A. It affects the average exposure to radiation

Duty cycle is a factor because it affects the average exposure to radiation. RF exposure limits are based on average exposure over time. A transmitter that is on less often gives a lower average exposure.

Tip: Duty cycle sets the average.

T0C11

What is the definition of duty cycle during the averaging time for RF exposure?

  1. A. The difference between the lowest and highest power output of a transmitter
  2. B. The difference between the PEP and the average power output of a transmitter
  3. C. The percentage of time that a transmitter is transmitting
  4. D. The percentage of time that a transmitter is not transmitting
Show the answer and explanation

Answer: C. The percentage of time that a transmitter is transmitting

Duty cycle is the percentage of time that a transmitter is transmitting during the averaging time. For example, transmitting half the time is a 50 percent duty cycle. It is not a power difference.

Tip: Duty cycle = percent of time transmitting.

T0C12

How does RF radiation differ from ionizing radiation (radioactivity)?

  1. A. RF radiation does not have sufficient energy to cause chemical changes in cells and damage DNA
  2. B. RF radiation can only be detected with an RF dosimeter
  3. C. RF radiation is limited in range to a few feet
  4. D. RF radiation is perfectly safe
Show the answer and explanation

Answer: A. RF radiation does not have sufficient energy to cause chemical changes in cells and damage DNA

RF radiation does not have enough energy to cause chemical changes in cells and damage DNA, unlike ionizing radiation. That does not make it perfectly safe: strong RF can heat body tissue and cause burns. That is why exposure limits exist.

Tip: RF doesn't break DNA, but it can burn.

T0C13

Who is responsible for ensuring that no person is exposed to RF energy above the FCC exposure limits?

  1. A. The FCC
  2. B. The station licensee
  3. C. Anyone who is near an antenna
  4. D. The local zoning board
Show the answer and explanation

Answer: B. The station licensee

The station licensee is responsible for ensuring that no person is exposed to RF energy above the FCC limits. The FCC sets the rules, but the licensee must evaluate the station and control exposure. This includes family members and neighbors.

Tip: Your station, your responsibility.

Practice T0 with scoring Take a 35-question practice exam