Ham Tech Prep

General › G0

G0 Electrical and RF Safety

25 questions in the pool. Your exam will include 2, one from each group below.

Practice G0 now

G0A

RF safety principles, rules, and guidelines; routine station evaluation

G0A01

What is one way that RF energy can affect human body tissue?

  1. A. It heats body tissue
  2. B. It causes radiation poisoning
  3. C. It causes the blood count to reach a dangerously low level
  4. D. It cools body tissue
Show the answer and explanation

Answer: A. It heats body tissue

RF energy heats body tissue, much like a microwave oven heats food. It is non-ionizing, so it does not cause radiation poisoning.

Tip: RF heats tissue.

G0A02

Which of the following is used to determine RF exposure from a transmitted signal?

  1. A. Its duty cycle
  2. B. Its frequency
  3. C. Its power density
  4. D. All these choices are correct
Show the answer and explanation

Answer: D. All these choices are correct

RF exposure depends on the signal's power density, its frequency (which affects how the body absorbs it), and its duty cycle (how much of the time it is on). So all of these are used.

Tip: Power density, frequency, duty cycle: all count.

G0A03

How can you determine that your station complies with FCC RF exposure regulations?

  1. A. By calculation based on FCC OET Bulletin 65
  2. B. By calculation based on computer modeling
  3. C. By measurement of field strength using calibrated equipment
  4. D. All these choices are correct
Show the answer and explanation

Answer: D. All these choices are correct

You can show compliance by calculation with FCC OET Bulletin 65, by computer modeling, or by measuring field strength with calibrated equipment. Any of these methods is acceptable.

Tip: Calculate, model, or measure.

FCC rule reference: Part 97.13(c)(1)

G0A04

What does “time averaging” mean when evaluating RF radiation exposure?

  1. A. The average amount of power developed by the transmitter over a specific 24-hour period
  2. B. The average time it takes RF radiation to have any long-term effect on the body
  3. C. The total time of the exposure
  4. D. The total RF exposure averaged over a certain period
Show the answer and explanation

Answer: D. The total RF exposure averaged over a certain period

Time averaging means the total RF exposure is averaged over a certain period, such as 6 or 30 minutes. Brief high exposure can be acceptable if the average stays within limits.

Tip: Exposure is averaged over time.

G0A05

What must you do if an evaluation of your station shows that the RF energy radiated by your station exceeds permissible limits for possible human absorption?

  1. A. Take action to prevent human exposure to the excessive RF fields
  2. B. File an Environmental Impact Statement (EIS-97) with the FCC
  3. C. Secure written permission from your neighbors to operate above the controlled MPE limits
  4. D. All these choices are correct
Show the answer and explanation

Answer: A. Take action to prevent human exposure to the excessive RF fields

If your station exceeds permissible exposure limits, you must take action to prevent people from being exposed to those excessive RF fields. Neighbor permission does not make excess exposure acceptable.

Tip: Over the limit? Keep people out of it.

FCC rule reference: Part 97.13(c)(2), 1.1307(b)

G0A06

What must you do if your station fails to meet the FCC RF exposure exemption criteria?

  1. A. Perform an RF exposure evaluation in accordance with FCC OET Bulletin 65
  2. B. Contact the FCC for permission to transmit
  3. C. Perform an RF exposure evaluation in accordance with World Meteorological Organization guidelines
  4. D. Use an FCC-approved band-pass filter
Show the answer and explanation

Answer: A. Perform an RF exposure evaluation in accordance with FCC OET Bulletin 65

If your station does not qualify for an exemption, you must perform an RF exposure evaluation, for example using FCC OET Bulletin 65. You do not need FCC permission to transmit.

Tip: Not exempt? Evaluate using OET Bulletin 65.

FCC rule reference: Part 97.13(c)(2), 1.1307(1)(b)(3)(i)

G0A07

What is the effect of modulation duty cycle on RF exposure?

  1. A. A lower duty cycle permits greater power levels to be transmitted
  2. B. A higher duty cycle permits greater power levels to be transmitted
  3. C. Low duty cycle transmitters are exempt from RF exposure evaluation requirements
  4. D. High duty cycle transmitters are exempt from RF exposure requirements
Show the answer and explanation

Answer: A. A lower duty cycle permits greater power levels to be transmitted

Exposure limits use time-averaged power. A lower duty cycle means the transmitter is on less of the time, so greater power levels can be transmitted within the limits.

Tip: Less on-time, more power allowed.

G0A08

Which of the following steps must an amateur operator take to ensure compliance with RF safety regulations?

  1. A. Post a copy of FCC Part 97.13 in the station
  2. B. Notify neighbors within a 100-foot radius of the antenna of the existence of the station and power levels
  3. C. Perform a routine RF exposure evaluation and prevent access to any identified high exposure areas
  4. D. All these choices are correct
Show the answer and explanation

Answer: C. Perform a routine RF exposure evaluation and prevent access to any identified high exposure areas

To comply with RF safety rules, you perform a routine RF exposure evaluation and prevent access to any high exposure areas identified. Posting rules or notifying neighbors is not required.

Tip: Evaluate, then keep people out of hot spots.

FCC rule reference: Part 97.13(c)(2)

G0A09

What type of instrument can be used to accurately measure an RF field strength?

  1. A. A receiver with digital signal processing (DSP) noise reduction
  2. B. A calibrated field strength meter with a calibrated antenna
  3. C. An SWR meter with a peak-reading function
  4. D. An oscilloscope with a high-stability crystal marker generator
Show the answer and explanation

Answer: B. A calibrated field strength meter with a calibrated antenna

Accurate RF field strength measurement requires a calibrated field strength meter with a calibrated antenna. SWR meters and oscilloscopes do not measure field strength in space.

Tip: Measure fields with calibrated meter and antenna.

G0A10

What should be done if evaluation shows that a neighbor might experience more than the allowable limit of RF exposure from the main lobe of a directional antenna?

  1. A. Change to a non-polarized antenna with higher gain
  2. B. Use an antenna with a higher front-to-back ratio
  3. C. Take precautions to ensure that the antenna cannot be pointed in their direction when they are present
  4. D. All these choices are correct
Show the answer and explanation

Answer: C. Take precautions to ensure that the antenna cannot be pointed in their direction when they are present

If a neighbor could be overexposed by the main lobe of a beam, take precautions so the antenna cannot be pointed toward them when they are present. Simply changing antennas does not reliably fix it.

Tip: Do not point the beam at people.

G0A11

What precaution should be taken if you install an indoor transmitting antenna?

  1. A. Locate the antenna close to your operating position to minimize feed-line radiation
  2. B. Position the antenna along the edge of a wall to reduce parasitic radiation
  3. C. Make sure that MPE limits are not exceeded in occupied areas
  4. D. Make sure the antenna is properly shielded
Show the answer and explanation

Answer: C. Make sure that MPE limits are not exceeded in occupied areas

An indoor antenna puts RF close to people, so you must make sure MPE (maximum permissible exposure) limits are not exceeded in occupied areas.

Tip: Indoor antenna: check MPE where people are.

G0A12

What stations are subject to the FCC rules on RF exposure?

  1. A. All commercial stations; amateur radio stations are exempt
  2. B. Only stations with antennas lower than one wavelength above the ground
  3. C. Only stations transmitting more than 500 watts PEP
  4. D. All stations with a time-averaged transmission of more than one milliwatt
Show the answer and explanation

Answer: D. All stations with a time-averaged transmission of more than one milliwatt

FCC RF exposure rules apply to all stations with a time-averaged transmission of more than one milliwatt, including amateur stations. Some stations may qualify for exemption from evaluation, but the rules still apply.

Tip: Over 1 milliwatt: RF rules apply.

FCC rule reference: Part 1.1307(1)(b)(3)(i)(A)

G0B

Station safety: electrical shock, grounding, fusing, interlocks, and wiring; antenna and tower safety

G0B01

Which wire or wires in a four-conductor 240 VAC circuit should be attached to fuses or circuit breakers?

  1. A. Only the hot wires
  2. B. Only the neutral wire
  3. C. Only the ground wire
  4. D. All wires
Show the answer and explanation

Answer: A. Only the hot wires

Only the hot wires should be fused or switched by breakers. Interrupting the neutral or ground could leave equipment energized and unsafe.

Tip: Fuse the hots only.

G0B02

According to the National Electrical Code, what is the minimum wire size that may be used safely for wiring with a 20-ampere circuit breaker?

  1. A. AWG number 20
  2. B. AWG number 16
  3. C. AWG number 12
  4. D. AWG number 8
Show the answer and explanation

Answer: C. AWG number 12

The National Electrical Code requires at least AWG 12 wire for a 20-ampere circuit. Smaller gauge numbers mean thicker wire, and AWG 14 is only good for 15 amps.

Tip: 20 amps needs AWG 12.

G0B03

Which size of fuse or circuit breaker would be appropriate to use with a circuit that uses AWG number 14 wiring?

  1. A. 30 amperes
  2. B. 25 amperes
  3. C. 20 amperes
  4. D. 15 amperes
Show the answer and explanation

Answer: D. 15 amperes

AWG 14 wire is rated for 15 amperes, so use a 15-ampere fuse or breaker. A larger breaker could let the wire overheat before tripping.

Tip: AWG 14 = 15 amps.

G0B04

Where should the station's lightning protection ground system be located?

  1. A. As close to the station equipment as possible
  2. B. Outside the building
  3. C. Next to the closest power pole
  4. D. Parallel to the water supply line
Show the answer and explanation

Answer: B. Outside the building

The lightning protection ground system should be located outside the building. This keeps lightning current from passing through the house and station.

Tip: Lightning ground goes outside.

G0B05

Which of the following conditions will cause a ground fault circuit interrupter (GFCI) to disconnect AC power?

  1. A. Current flowing from one or more of the hot wires to the neutral wire
  2. B. Current flowing from one or more of the hot wires directly to ground
  3. C. Overvoltage on the hot wires
  4. D. All these choices are correct
Show the answer and explanation

Answer: B. Current flowing from one or more of the hot wires directly to ground

A GFCI trips when current flows from a hot wire directly to ground instead of returning through the neutral. Normal hot-to-neutral current is how equipment operates.

Tip: GFCI catches current leaking to ground.

G0B06

Which of the following is covered by the National Electrical Code?

  1. A. Acceptable bandwidth limits
  2. B. Acceptable modulation limits
  3. C. Electrical safety of the station
  4. D. RF exposure limits of the human body
Show the answer and explanation

Answer: C. Electrical safety of the station

The National Electrical Code covers electrical safety, including the station's wiring and grounding. Bandwidth, modulation, and RF exposure are covered by FCC rules.

Tip: NEC = electrical safety.

G0B07

Which of these choices should be observed when climbing a tower using a safety harness?

  1. A. Always hold on to the tower with one hand
  2. B. Confirm that the harness is rated for the weight of the climber and that it is within its allowable service life
  3. C. Ensure that all heavy tools are securely fastened to the harness
  4. D. All these choices are correct
Show the answer and explanation

Answer: B. Confirm that the harness is rated for the weight of the climber and that it is within its allowable service life

Before climbing, confirm the harness is rated for the climber's weight and is within its allowable service life. An old or underrated harness can fail.

Tip: Check harness rating and age.

G0B08

What should be done before climbing a tower that supports electrically powered devices?

  1. A. Notify the electric company that a person will be working on the tower
  2. B. Make sure all circuits that supply power to the tower are locked out and tagged
  3. C. Unground the base of the tower
  4. D. All these choices are correct
Show the answer and explanation

Answer: B. Make sure all circuits that supply power to the tower are locked out and tagged

Before climbing a tower with powered devices, make sure all circuits that supply power to the tower are locked out and tagged. This prevents anyone from energizing them while you climb.

Tip: Lock out and tag out first.

G0B09

Which of the following is true of an emergency generator installation?

  1. A. The generator should be operated in a well-ventilated area
  2. B. The generator must be insulated from ground
  3. C. Fuel should be stored near the generator for rapid refueling in case of an emergency
  4. D. All these choices are correct
Show the answer and explanation

Answer: A. The generator should be operated in a well-ventilated area

Generators produce deadly carbon monoxide, so they must be operated in a well-ventilated area. Fuel should not be stored nearby, and the generator should be grounded.

Tip: Generators need fresh air: carbon monoxide kills.

G0B10

Which of the following is a danger from lead-tin solder?

  1. A. Lead can contaminate food if hands are not washed carefully after handling the solder
  2. B. High voltages can cause lead-tin solder to disintegrate suddenly
  3. C. Tin in the solder can “cold flow,” causing shorts in the circuit
  4. D. RF energy can convert the lead into a poisonous gas
Show the answer and explanation

Answer: A. Lead can contaminate food if hands are not washed carefully after handling the solder

Lead from solder can transfer to food if you do not wash your hands carefully after handling it. Lead is toxic when ingested.

Tip: Wash your hands after soldering.

G0B11

Which of the following is required for lightning protection ground rods?

  1. A. They must be bonded to all buried water and gas lines
  2. B. Bends in ground wires must be made as close as possible to a right angle
  3. C. Lightning grounds must be connected to all ungrounded wiring
  4. D. They must be bonded together with all other grounds
Show the answer and explanation

Answer: D. They must be bonded together with all other grounds

All lightning protection ground rods must be bonded together with all other grounds. This keeps everything at the same potential so lightning does not jump between grounds.

Tip: Bond all grounds together.

G0B12

What is the purpose of a power supply interlock?

  1. A. To prevent unauthorized changes to the circuit that would void the manufacturer's warranty
  2. B. To shut down the unit if it becomes too hot
  3. C. To ensure that dangerous voltages are removed if the cabinet is opened
  4. D. To shut off the power supply if too much voltage is produced
Show the answer and explanation

Answer: C. To ensure that dangerous voltages are removed if the cabinet is opened

A power supply interlock removes dangerous voltages when the cabinet is opened. This protects you from shock while working inside.

Tip: Open the case, power is cut.

G0B13

Where should lightning arrestors be located?

  1. A. Where the feed lines enter the building
  2. B. On the antenna, opposite the feed point
  3. C. In series with each ground lead
  4. D. At the closest power pole ground electrode
Show the answer and explanation

Answer: A. Where the feed lines enter the building

Lightning arrestors should be located where the feed lines enter the building. That diverts lightning surges to ground before they get inside.

Tip: Arrestors at the building entry point.

Practice G0 with scoring Take a 35-question practice exam